volumes-pièces-deau-1
volumes-pièces-deau-2
volumes-pièces-deau-3
volumes-pièces-deau

Electrican standards

The standards set the rules for electrical installations in residential premises in order to ensure user safety and the protection of property. You must know and comply with the standards to avoid any electric shock or fire.

Normative references about luminaires:

  • Luminaires : general prescription and tests. NF EN 60598-1 edition 8: 2015
  • Low voltage electrical installations NFC 15100 / A5: 2015

The different volumes must be equipped with a high sensitivity differential device of 30 mA.

Note : The characteristics of equipment installed astride several VOLUMES must comply with those of the most restrictive VOLUME concerned (equipment installed astride volumes 1 and 2 is considered to be VOLUME 1).

2P + E SOCKET: The 2P + E socket must be located outside the volume. A shaver socket with separation transformer can be located in volume 2.

FALSE CEILING: If the room has a false ceiling, then the space above it will be considered out of volume.

bleu_clair Mini. IP67
Apparatus prohibited
bleu_fonce Mini. IP44 , Class III
max. 12V in alternate current
or max. 30V in direct current
gris Mini. IP44, Class II or III
max. 12V in alternate current